Generac’s Closed Transition 1200-1600A SE transfer switch ensures seamless power transitions, designed to eliminate power interruptions even during load transfer. It is built to meet the stringent requirements of Mission Critical markets, providing unmatched reliability and performance. Its compact design and 100% rating provide cost-saving benefits without compromising functionality. This transfer switch offers cutting-edge technology for breaker coordination with its industry-leading 100kA WCR rating.

Features may include:

Seamless Closed Transition:
  • Eliminates power interruptions, ensuring an uninterrupted load transfer.
Size Offering:
  • Available up to 1600A, supporting 480 VAC and up to 60 Hz.
High Withstand and Closing Ratings:
  • Designed with 100kA WCR for optimal breaker coordination.
Generac Patented Design:
  • Double-throw robust construction featuring a patented contactor design.
Generac Designed Control:
  • Includes front-accessible controls, USB functionality, and up to 60 minutes of built-in battery backup.
Compact Footprint:
  • 100% rated design reduces the need to oversize, saving space and costs.
Applications
  • The TX Closed Transition SE Transfer Switch is the preferred choice for:
  • Healthcare Facilities: Ensuring smooth operation of critical life-saving equipment.
  • Data Centers: Providing reliable, interruption-free transitions.
  • Retail and Manufacturing Facilities: Supporting operational continuity during outages.
Certifications
  • ETL Certified to UL 1008: Exceeds U.S. safety and performance standards for industrial applications.

Electric

Electrical 1200A 3 Pole Normal 75 °C Wire: (4) 4/0-500MCM or (3) 500-750MCM | Standby Source 75 °C Wire: (4) 750 – 4/0 | Load 75 °C Wire: (4) 750 – 4/0 | Neutral Connection: (12) 750 – 1/0 | Ground Connection: (15) 600-#4 or (30) 250-1/0 | 1200A 3 Pole Ampere Rating: 1200 A / 1600 A | 1200A 3 Pole WCR Ratings: 100 kA / 100 kA | 1200A 3 Pole Voltage: 480 V / 480 V | 1200A 4 Pole Normal 75 °C Wire: (4) 4/0-500MCM or (3) 500-750MCM | 1200A 4 Pole Standby Source 75 °C Wire: (4) 750 – 4/0 | 1200A 4 Pole Load 75 °C Wire: (4) 750 – 4/0 | 1200A 4 Pole Neutral Connection: (4) 750 – 1/0 | 1200A 4 Pole Ground Connection: (15) 600-#4 or (30) 250-1/0 | 1200A 4 Pole Ampere Rating: 1200 A /1600 A | 1200A 4 Pole: WCR Ratings: 100 kA / 100 kA | 1200A 4 Pole: Voltage: 480 V / 480 V | 1600A 3 Pole Normal 75 °C Wire: (4) 500 – 1000 | 1600A 3 Pole Standby Source 75 °C Wire: (6) 750 – 4/0 | 1600A 3 Pole Load 75 °C Wire: (6) 750 – 4/0 | 1600A 3 Pole Neutral Connection: (20) 750 – 1/0 | Ground Connection: (20) 600-#4 or (40) 250-1/0 | 1600A 3 Pole Ampere Rating: 1200 A/ 1600 A | 1600A 3 Pole WCR Ratings: 100 kA / 100 kA | 1600A 3 Pole Voltage: 480 V / 480 V | 1600A 4 Pole Normal 75 °C Wire: (4) 500 – 1000 | 1600A 4 Pole Standby Source 75 °C Wire: (6) 750 – 4/0 | 1600A 4 Pole Load 75 °C Wire: (6) 750 – 4/0 | 1600A 4 Pole Neutral Connection: (8) 750 – 1/0 | 1600A 4 Pole Ground Connection: (20) 600-#4 or (40) 250-1/0 | 1600A 4 Pole Ampere Rating: 1200 / 1600 | 1600A 4 Pole WCR Rating: 100 kA / 100 kA | 1600A 4 Pole Voltage: 480 V / 480 V

Operational

Operating Temperature, Maximum -4 ° to 158 °F (-20 ° to 70 °C)

Dimensions

Dimensions 1200A 3 Pole: 16 in (407 mm) / 3.6 in (91 mm) / 33.7 in (856 mm) / 26.2 in (666 mm) / 27.6 in (701 mm) / 28.9 in (733 mm) / 30.3 in (768 mm) / 46.1 in (1172 mm) / 75.3 in (1914 mm) / 74.5 in (1891 mm) / 75.7 in (1923 mm) / 19.6 in (498 mm) / 40 in (1017 mm) / 2.4 in (62 mm) / 4.4 in (111 mm) / 6.9 in (175 mm) / 8.9 in (225 mm) / 16.6 in (421 mm) | 1200A 4 Pole: 16 in (407 mm) / 3.6 in (91 mm) / 33.7 in (856 mm) / 26.2 in (666 mm) / 27.6 in (701 mm) / 28.9 in (733 mm) / 30.3 in (768 mm) / 46.1 in (1172 mm) / 75.3 in (1914 mm) / 74.5 in (1891 mm) / 75.7 in (1923 mm) / 19.6 in (498 mm) / 40 in (1017 mm) / 2.4 in (62 mm) / 4.4 in (111 mm) / 6.9 in (175 mm) / 8.9 in (225 mm) / 16.6 in (421 mm) | 1600A 3 Pole: 14.2 in (360 mm) / 4.8 in (123 mm) / 40.2 in (1021 mm) / 24.1 in (611 mm) / 25.4 in (646 mm) / 26.7 in (677 mm) / 28.1 in (713 mm) / 45.2 in (1149 mm) / 24.6 in (624 mm) / 28.6 in (726 mm) / 30 in (761 mm) / 20.2 in (512 mm) / 2.7 in (68 mm) / 4.6 in (118 mm) / 7.2 in (182 mm) / 9.1 in (231 mm) / 13.7 in (348 mm) | 1600A 4 Pole: 19 in (483 mm) / 4.8 in (123 mm) / 45 in (1144 mm) / 24.1 in (611 mm) / 24.5 in (646 mm) / 26.7 in (677 mm) / 28.1 in (713 mm) / 45.2 in (1149 mm) / 76.6 in (1944 mm) / 75.7 in (1922 mm) / 78.3 in (1989 mm) / 20.2 in (512 mm) / 2.7 in (68 mm) / 4.6 in (118 mm) / 7.2 in (182 mm) / 9.1 in (231 mm) / 13.7 in (348 mm)

Weights

Weight 1200A 3 Pole: 880 (399.1) | 1200A 4 Pole: 980 lbs (445 kg) | 1600A 3 Pole: 1275 lbs (578 kg) | 1600A 4 Pole: 1385 lbs (628 kg)

Features

Features Floor Mounted, Wall Secured | Cable Entry is Top or Bottom | Double-Throw, Stored Energy Transfer Mechanism | Graphical LCD-Based Display for Programming, System Diagnostics and Help Menu Display Mimic | Diagram with Source Available and Connected | Method of Transfer: Closed Transition | Mechanically Interlocked to Prevent Connection of Both Sources | Modbus® RTU | TXC 100 Controller | Voltage Agnostic | High Withstand and Closing Ratings | Heater Kit Standard on All 3R Enclosures | Auxiliary Input Includes: Permissive Inputs (24VDC) | General Alarm Indication | Expandable Input/Output Board Module Includes: 4 Relay Outputs and 3 Optically Isolated Inputs | Three Phase Under and Over Voltage Sensing on Normal and Emergency Sources | Under and Over Frequency Sensing on Normal and Emergency | Selectable Settings: Single or Three Phase Voltage | Sensing on Normal and Emergency 60 Hz | Phase Sequence Sensing for Phase Sensitive Loads | 2-wire Start | 3-wire Start from C Contact for Circuit Monitoring | Switch Position Indication (2 Form C) | Signal Before Transfer (Elevator) | General Alarm | Emergency Inhibit (Permissive & Load Shed) | Go to Emergency | Manual Generator Retransfer | Front Programmable Control Reduces PPE Needs and Arc Flash Hazard | Built in Battery Backup – Increases Switch Reliability and Reduces Switch Transition Time to Alternate Source | Battery Backup Able to Power the Controller for up to 60 Minutes in the Event of No Source Availability | Accessible USB Port for Easy Data Downloads, Firmware Updates without Requiring PPE, Reducing the Risk of Arc Flash | All Amp Nodes Available in Delayed Transition | Heater Programmable through Control for Desired Temperature and Humidity Settings | Front Accessible Customer Connections | Time-Stamped Event History Log | Programmable Exerciser – Daily, Weekly, Biweekly, Monthly

Warranty

Warranty 2 Year Limited Warranty