2025 Generac Mobile Industrial Transfer Switches 301-800-1000a
- Year 2025
- Make Generac Mobile
- Model Industrial Transfer Switches
2025 Generac Mobile Industrial Transfer Switches 301-800-1000a
New to the Generac industrial transfer switch line is the TX Series. The TX Series switches are both Generac designed and built in house with exceptional features that meet, and exceed, any application needs. These transfer switches have some of the highest withstand and closing ratings (WCR). In addition, these switches offer no PPE needed for controller use, firmware updates, or data downloads when the enclosure door is installed.
Electric
Electrical
Normal 75 °C Wire: (4) 500 - 4/0 | Normal Wire Lug Torque: 375 lb/in (42.4 Nm) | Standby/Load Source 75 °C Wire: (4) 750 - 4/0 | Standby/Load Wire Lug Torque: 620 lb/in (70 Nm) | Neutral Connection: (16) 750–1/0 | Neutral Wire Lug Torque: 500 lb/in (56.5 Nm) | Ground Connection: (10) 600–4 or (20) 250–1/0 | Ground Wire Lug Torque: 375 lb/in (42.4 Nm) | UL 1008 Withstand and Closing Ratings Ampere Rating: 800/800/1000/1000 | UL 1008 Withstand and Closing Ratings Service Entrance: 100 kA / 65 kA / 100 kA / 65 kA | UL 1008 Withstand and Closing Ratings Voltage: Up to 480 / Up to 600 / Up to 480 / Up to 600
Dimensions
Dimensions
800A 2 & 3 Pole: 13.0 in (331 mm) / 2.6 in (66 mm) / 31.7 in (805 mm) / 26.4 in (669 mm) / 27.3 in (703 mm) / 29.0 in (736 mm) / 30.3 in (770 mm) / 47.1 in (1195 mm) / 33.1 in (841 mm) / 27.2 in (691 mm) / 28.6 in (726 mm) / 2.4 in (62 mm) / 4.4 in (111 mm) / 6.9 in (175 mm) / 8.9 in (175 mm) / 17.0 in (432 mm) | 800A 4 Pole: 13.0 in (331 mm) / 2.6 in (66 mm) / 31.7 in (805 mm) / 26.4 in (669 mm) / 27.3 in (703 mm) / 29.0 in (736 mm) / 30.3 in (770 mm) / 47.1 in (1195 mm) / 33.1 in (841 mm) / 27.2 in (691 mm) / 28.6 in (726 mm) / 2.4 in (62 mm) / 4.4 in (111 mm) / 6.9 in (175 mm) / 8.9 in (175 mm) / 17.0 in (432 mm) | 1000A 2 & 3 Pole: 13.0 in (331 mm) / 2.6 in (66 mm) / 31.7 in (805 mm) / 26.4 in (669 mm) / 27.3 in (703 mm) / 29.0 in (736 mm) / 30.3 in (770 mm) / 47.1 in (1195 mm) / 33.1 in (841 mm) / 27.2 in (691 mm) / 28.6 in (726 mm) / 2.4 in (62 mm) / 4.4 in (111 mm) / 6.9 in (175 mm) / 8.9 in (175 mm) / 17.0 in (432 mm) | 1000A 4 Pole: 13.0 in (331 mm) / 2.6 in (66 mm) / 31.7 in (805 mm) / 26.4 in (669 mm) / 27.3 in (703 mm) / 29.0 in (736 mm) / 30.3 in (770 mm) / 47.1 in (1195 mm) / 33.1 in (841 mm) / 27.2 in (691 mm) / 28.6 in (726 mm) / 2.4 in (62 mm) / 4.4 in (111 mm) / 6.9 in (175 mm) / 8.9 in (175 mm) / 17.0 in (432 mm)
Weights
Weight
800A 2 & 3 Pole: 840 lbs (381 kg) / 915 lbs (415 kg) | 800A 4 Pole: 990 lbs (449 kg) | 1000A 2 & 3 Pole: 840 lbs (381 kg) / 915 lbs (415 kg) | 1000A 4 Pole: 990 lbs (449 kg)
Features
Features
Floor Mounted, Wall Secured | Cable Entry is Top or Bottom | Double-Throw, Stored Energy Transfer Mechanism | Can be Electrically Isolated while Energized | Graphical LCD-Based Display for Programming, System Diagnostics and Help Menu Display Mimic | Diagram with Source Available and Connected | Method of Transfer: Closed Transition | Mechanically Interlocked to Prevent Connection of Both Sources | Modbus® RTU | TXC 100 Controller | Operating Temperature -4 ° to 158 °F (-20 ° to 70 °C) | Removable Top and Bottom Plates for Ease of Entry | Voltage Agnostic | High Withstand and Closing Ratings | Heater Kit Standard on All 3R Enclosures | Auxiliary Input Includes: Permissive Inputs (24VDC) | General Alarm Indication | Expandable Input/Output Board Module Includes: 4 Relay Outputs and 4 Optically Isolated Inputs | Three Phase Under and Over Voltage Sensing on Normal and Emergency Sources | Under and Over Frequency Sensing on Normal and Emergency | Selectable Settings: Single or Three Phase Voltage | Sensing on Normal and Emergency 60 Hz | Phase Sequence Sensing for Phase Sensitive Loads | 2-wire Start | 3-wire Start from C Contact for Circuit Monitoring | Switch Position Indication (2 Form C) | Signal Before Transfer (Elevator) | General Alarm | Emergency Inhibit (Permissive & Load Shed) | Go to Emergency | Manual Generator Retransfer | Front Programmable Control Reduces PPE Needs and Arc Flash Hazard | Built in Battery Backup – Increases Switch Reliability and Reduces Switch Transition Time to Alternate Source | Battery Backup Able to Power the Controller for up to 60 Minutes in the Event of No Source Availability | Generator Battery Backup for Controller | Accessible USB Port for Easy Data Downloads, Firmware Updates without Requiring PPE, Reducing the Risk of Arc Flash | All Amp Nodes Offered with Delayed Transition | Heater Programmable through Control for Desired Temperature and Humidity Settings | Front Accessible Customer Connections | Time-Stamped Event History Log | Programmable Exerciser – Daily, Weekly, Biweekly, Monthly |
Warranty
Warranty
2 Year Standard Warranty