2025 Generac Mobile Industrial Transfer Switches 611-600a
New to the Generac industrial transfer switch line is the TX Series. The TX Series switches are both Generac designed and built in house with exceptional features that meet, and exceed, any application needs. These transfer switches have some of the highest withstand and closing ratings (WCR) with 3 cycle ratings available. In addition, these switches offer no PPE needed for controller use, firmware updates, or data downloads when the enclosure door is installed.
Electric
Electrical
600A 2 & 3 Pole/600 A 4 Pole Normal 75 °C Wire: (2) 750 Kcmil - 2 | 600A 2 & 3 Pole/600 A 4 Pole Standby Source 75 °C Wire: (2) 750 Kcmil - 2 | 600A 2 & 3 Pole/600 A 4 Pole Load 75 °C Wire: (2) 750 Kcmil - 2 | 600A 2 & 3 Pole/600 A 4 Pole Neutral Connection: (10) 600 - 4 or (20) 250 - 1/0 | 600A 2 & 3 Pole/600 A 4 Pole Ground Connection: (10) 350 Kcmil - 6 | 600A 2 & 3 Pole/600 A 4 Pole Ampere Rating: 600 | 600A 2 & 3 Pole/600 A 4 Pole 3-Cycle Rating (kA): 50 | 600A 2 & 3 Pole/600 A 4 Pole Fuse Rating (Class L): 200 kA | 600A 2 & 3 Pole/600 A 4 Pole Fuse Size (Class L): 2000 A | 600A 2 & 3 Pole/600 A 4 Pole Voltage: Up to 600 V | 600A 2 & 3 Pole - 600 A 4 Pole Normal 75 °C Wire: (2) 750 Kcmil - 2 | 600A 2 & 3 Pole - 600 A 4 Pole Standby Source 75 °C Wire: (2) 750 Kcmil - 2 | 600A 2 & 3 Pole - 600 A 4 Pole Load 75 °C Wire: (2) 750 Kcmil - 2 | 600A 2 & 3 Pole - 600 A 4 Pole Neutral Connection: (8) 600 - 4 or (16) 250 - 1/0 | 600A 2 & 3 Pole - 600 A 4 Pole Ground Connection: (10) 350 Kcmil - 6 | 600A 2 & 3 Pole - 600 A 4 Pole Ampere Rating: 600 | 600A 2 & 3 Pole - 600 A 4 Pole 3-Cycle Rating (kA): 50 | 600A 2 & 3 Pole - 600 A 4 Pole Fuse Rating (Class L): 200 kA | 600A 2 & 3 Pole - 600 A 4 Pole Fuse Size (Class L): 2000 A | 600A 2 & 3 Pole - 600 A 4 Pole Voltage: Up to 600V
Operational
Operating Temperature, Maximum
-4° to 158°F (-20° to 70°C)
Dimensions
Dimensions
600A 2 & 3 Pole: 18.1 in (495.5 mm) / 2.8 in (70.3 mm) / 15.13 in (384.3 mm) / 16.51 in (419.3 mm) / 39.0 in (990.6 mm) / 40.4 in (1025.5 mm) / 41.64 in (1057.7 mm) / 43.02 in (1092.6 mm) / 9.65 in (245.2 mm) / 8.17 in (207.6 mm) / 4.93 in (125.2 mm) / 3.45 in (87.6 mm) / 7.29 in (185.2 mm) / 5.81 in (147.6 mm) / 51.3 in (1303.8 mm) / 54.5 in (1384 mm) / 1.74 in (44.2 mm) / 4.25 in (107.9 mm) | 600 A 4 Pole: 16.2 in (411.5 mm) / 2.8 in (70.3 mm) / 15.13 in (384.3 mm) / 16.51 in (419.3 mm) / 39.0 in (990.6 mm) / 40.4 in (1025.5 mm) / 41.64 in (1057.7 mm) / 43.02 in (1092.6 mm) / 9.65 in (245.2 mm) / 8.17 in (207.6 mm) / 4.93 in (125.2 mm) / 3.45 in (87.6 mm) / 7.29 in (185.2 mm) / 5.81 in (147.6 mm) / 51.3 in (1303.8 mm) / 54.5 in (1384 mm) / 1.74 in (44.2 mm) / 4.25 in (107.9 mm) | 600A 2 & 3 Pole - 600 A 4 Pole: 15.66 in (397.8 mm) / 2.75 in (69.9 mm) / 23.5 in (597.0 mm) / 24.9 in (632.0 mm) / 47.31 in (1201.6 mm) / 48.68 in (1236.5 mm) / 49.97 in (1269.2 mm) / 51.34 in (1304.1 mm) / 9.55 in (242.5 mm) / 8.20 in (208.2 mm) / 4.82 in (122.5 mm) / 3.47 in (88.2 mm) / 5.83 in (148.2 mm) / 7.18 in (182.5 mm)
Weights
Weight
600A 2 & 3 Pole: 2–Pole 231 lbs (104.8 kg) / 3–Pole 245 lbs (111.1 kg) | 600 A 4 Pole: 259 lbs (117.5 kg) | 600A 2 & 3 Pole: 2–Pole: 496 lbs (225 kg) / 3–Pole: 510 lbs (231.3 kg) | 600 A 4 Pole: 542 lbs (237.7 kg)
Features
Features
Small Footprint, Results in Easy Mounting and Installation for Reduced Time and Costs | Wall Mount for Type 1 and 3R | Floor Mounted, Wall Secured for Type 12 | Cable Entry is Top or Bottom | Double-throw, stored energy transfer mechanism | Can be electrically isolated while energized | Graphical LCD-Based Display for Programming, System Diagnostics, and Help Menu Display Mimic | Diagram with Source Available and Connected LED Indicator | Method of Transfer: Open with Inphase Transition | Mechanically Interlocked to Prevent Connection of Both Sources | Modbus® RTU Communications | TXC 100 Controller | Removable Top and Bottom Plates for Ease of Entry | Voltage Agnostic | High Withstand and Closing Ratings | Heater Kit Standard on all 3R Enclosures | Auxiliary Output Includes: Two Wire Start, Signal Before Transfer, Fault, and a Programmable Relay Output | Auxiliary Input Includes: Permissive Inputs (24VDC) | General Alarm Indication | Three Phase Under and Over Voltage Sensing on Normal and Emergency Sources | Under and Over Frequency Sensing on Normal and Emergency | Selectable Settings: Single or Three Phase Voltage | Sensing on Normal and Emergency 60 Hz | Phase Sequence Sensing for Phase Sensitive Loads | 2-wire Start | 3-wire Start from C Contact for Circuit Monitoring | Switch Position Indication (2 Form C) | Signal Before Transfer (Elevator) | General Alarm | Emergency Inhibit (Permissive & Load Shed) | Go to Emergency (Demand Response) | Manual Generator Retransfer | Front Programmable Control Reduces PPE Needs and Arc Flash Hazard | Built in Battery Backup – Increases Switch Reliability and Reduces Switch Transition Time to Alternate Source | Battery Backup Able to Power the Controller for up to 60 Minutes in the Event of No Source Availability | Generator Battery Backup for Controller | Accessible USB Port for Easy Data Downloads, Firmware Updates without Requiring PPE, Reducing the Risk of Arc Flash | All Amp Nodes Offered with Delayed Transition | Heater Programmable through Control for Desired Temperature and Humidity Settings | Front Accessible Customer Connections | Time-Stamped Event History Log | Programmable Exerciser – Daily, Weekly, Biweekly, Monthly
Warranty
Warranty
2 Year Standard Warranty