2025 Generac Mobile Industrial Transfer Switches psts-100-1000a-se-rated
- Year 2025
- Make Generac Mobile
- Model Industrial Transfer Switches
2025 Generac Mobile Industrial Transfer Switches psts-100-1000a-se-rated
The Power Series Transfer Switch line features 3 different platforms with multiple technologies to offer the most flexible solutions up to 5,000 AMPs. All platforms are rated for 3 cycle operation with highly reliable mechanisms with safety interlocks. Service entrance models are 100 percent rated and available with integral overcurrent protection.
Features may include:
- Standard — Provides fast transfers and is an economical and easy-to-use choice for most facilities.
- Service Entrance — Provides a disconnect that interrupts excessive voltage and allows for manually disconnecting your facility from the electrical utility. Rated for full load transfers in critical operating, emergency, legally required, and optional power systems.
- Bypass Isolation — Designed for transfer switch applications where maintenance must be performed while maintaining continuous power to the load.
- Manual – Designed for applications having a need for a mobile generator, providing reliable and easy-to-use connections for safe and quick backup power connection.
- 100 – 5000 Amp
- Open with Time Delay Neutral or In-Phase Transfer
- Closed Transition
- Bypass Isolation
- Contactor, Power Frame, or Molded Case Breaker
- 2, 3, 4 Pole
- NEMA 1, 12, 3R, 4 & 4X
- UL1008/CSA/NFPA/NEC/ISO/ANSI/OSHPD/IEC
- Microprocessor Based Control
- Two Wire Start – Any Generator Controller
- Service Entrance and Non-Service Entrance Rated
Electric
Electrical
Amperes: 100/100/200-225/200-225/300/400/400/600/600/600 (Four Pole)/800/800-1,00 | Switch Type: HFD/HFD/HFD/HKD/HKD/HKD/HLD/HLD/HMDL/NB/HMDL/HNB | Normal and Standby Source: (1) #14-1/0 Cu/Al / (1) #14-1/0 Cu/Al / (1) #6-300 Cu/Al / (1) #3-350 Cu/Al / (1) #3-350 Cu/Al / (2) #1-500 Cu/Al / (1) 4/0-600 Cu/Al / (2) 3/0-350 Cu/Al / (2) #1-500 Cu/Al / (3) 3/0-400 Cu/Al /(3) 3/0-400 Cu/Al / (4) 4/0-500 Cu/Al | Load Connection: (1) #14-1/0 Cu/Al / (1) #14-1/0 Cu/Al / (1) #6-300 Cu/Al / (1) #6-350 Cu/Al / (1) #6-350 Cu/Al / (2) #1-500 Cu/Al / (2) #1-500 Cu/Al / (2) #1-500 Cu/Al / (2) #1-500 Cu/Al / (3) 3/0-400 Cu/Al / (3) 3/0-400 Cu/Al / (4) 4/0-500 Cu/Al | Neutral Connection: (3) #14-1/0 Cu/Al / (3) #14-1/0 Cu/Al / (3) #4-300 Cu/Al / (3) #4-350 Cu/Al / (3) #4-350 Cu/Al / (6) 250-350 Cu/Al / (6) 250-350 Cu/Al / (6) 250-350 Cu/Al / (6) 4/0-500 Cu/Al / (3) 3/0-400 Cu/Al / (12) 4/0-500 Cu/Al / (12) 4/0-500 Cu/Al | UL 1008 Withstand and Closing Ratings Ampere Rating: 100/200/225/300/400/600/800/1,000 | UL 1008 Withstand and Closing Ratings Service entrance (240 V-480 V-600 B) 100/200/225/300/400/600/800/1,000: 100 kA-65 kA-25 kA / 100 kA-65 kA-25 kA / 100 kA-65 kA-35 kA / 100 kA-65 kA-35 kA / 100 kA-65 kA-35 kA / 100 kA-65 kA-35 kA / 65 kA-50 kA-25 kA | UL 1008 Withstand and Closing Ratings, Max Fuse Rating 100/200/225/300/400/600/800/1,000: 200/400/400/400/400/1,200/1,600/1,600 | UL 1008 Withstand and Closing Ratings 100/200/225/300/400/600/800/1,000 Fuse Type: J, T/J, T/J, T/J, T/J, T/J, T/L/L | UL 1008 Withstand and Closing Ratings 100/200/225/300/400/600/800/1,000 Rating when Used with Upstream Fuse 600V: 200/200/200/200/200/200/200/200
Operational
Operating Temperature, Maximum
-4 ° to 158 °F (-20 ° to 70 °C)
Dimensions
Dimensions
Horizontal: 10.8 in (273 mm) | 10.8 in (273 mm) | 10.8 in (273 mm) | 11.0 in (279 mm) | 11.0 in (279 mm) | 16.0 in (406 mm) | 16.0 in (406 mm) | 16.0 in (406 mm) | 16.0 in (406 mm) | 16.0 in (406 mm) | 16.0 in (406 mm) | 16.0 in (406 mm) | Vertical: 46.4 in (1180 mm) | 34.3 in (904 mm) | 34.3 in (904 mm) | 45.5 in (1156 mm) | 53.5 in (1359 mm) | 61.5 in (1562 mm) | 51.5 in (1308 mm) | 62.5 in (1588 mm) | 75.2 in (1909 mm) | 75.2 in (1909 mm) | 75.2 in(1909 mm) | 75.2 in (1909 mm)
Height
47.5 in (1213 mm) | 35.6 in (904 mm) | 35.6 in (904 mm) | 48.0 in (1219 mm) | 56.0 in (1422 mm) | 64.0 in (1626 mm) | 64.0 in (1626 mm) | 64.0 in (1626 mm) | 76.7 in (1949 mm) | 76.7 in (1949 mm) | 76.7 in (1949 mm) | 76.7 in (1949 mm)
Width
20.8 in (529 mm) | 20.1 in (510 mm) | 20.1 in (510 mm) | 20.8 in (529 mm) | 20.8 in (529 mm) | 25.8 in (656 mm) | 25.8 in (656 mm) | 25.8 in (656 mm) | 25.8 in (656 mm) | 25.8 in (656 mm) | 25.8 in (656 mm) | 25.8 in (656 mm)
Depth, Maximum
15.2 in (387 mm) | 11.3 in (288 mm) | 13.3 in (339 mm) | 16.7 in (423 mm) | 16.7 in (423 mm) | 16.7 in (423 mm) | 16.7 in (423 mm) | 16.7 in (423 mm) | 17.8 in (451 mm) | 17.8 in (451 mm) | 17.8 in (451 mm) | 17.8 in (451 mm)
Weights
Weight
100: 232 lbs (105 kg) | 100: 150 lbs (68 kg) | 200-225: 150 lbs (68 kg) | 200-225: 305 lbs (138 kg) | 300: 295 lbs (134 kg) | 400: 340 lbs (150 kg) | 400: 425 lbs (193 kg) | 600: 475 lbs (214 kg) | 600: 480 lbs (218 kg) | 600 (Four-pole): 600 lbs (272 kg) | 800: 510 lbs (232 kg) | 800 – 1,000: 570 lbs (259 kg)
Features
Features
Double-Throw, Mechanically Interlocked Transfer Mechanism | High Withstand and Closing Ratings | LCD-Based Display for Programming, System Diagnostics and Help Menu Display | Mimic Diagram with Source Available and Connected LED Indication | Top, Bottom, and Side Cable Entry | Time-Stamped History Log | System TEST Pushbutton | Programmable Plant Exerciser – OFF, Daily, 7 Day Interval Selectable Run Time 0-600 Minutes No Load/Load with Failsafe | Safe Manual Operation Under Full Load with Permanently Affixed Operating Handle | Space Heater with Thermostat (NEMA 3R) | Modbus® RTU | Field Programmable Time Delays | ATC-300+ Controller | Three Phase Under and Over Voltage Sensing on Normal and Emergency Sources, Plus Load | Under and Over Frequency Sensing on Normal, Emergency and Load | Three Phase Sequence Sensing for Phase Sensitive Loads | Three Phase Voltage Unbalance and Loss Sensing | Source Available: Source-1 Present, 2-N.O. and 2-N.C. / Source-2 Present, 2-N.O. and 2-N.C. | Switch Position: Source-1 Position, 1-N.O. and 1-N.C. / Source-2 Position, 1-N.O. and 1-N.C. | Pre-Transfer Signal Contacts 1-N.O. and 1-N.C.