The Power Series Transfer Switch line features 3 different platforms with multiple technologies to offer the most flexible solutions up to 5,000 AMPs. All platforms are rated for 3 cycle operation with highly reliable mechanisms with safety interlocks. Service entrance models are 100 percent rated and available with integral overcurrent protection. These distinctive Generac models combine an automatic transfer switch with an isolation mechanism and a manual bypass switch to provide redundant power transfer and re-transfer capability for critical-need applications requiring consistent and uninterrupted power to the load.

Features may include:

  • 100 – 5000 Amp
  • Open with Time Delay Neutral or In-Phase Transfer
  • Closed Transition
  • Bypass Isolation
  • Contactor, Power Frame, or Molded Case Breaker
  • 2, 3, 4 Pole
  • NEMA 1, 12, 3R, 4 & 4X
  • UL1008/CSA/NFPA/NEC/ISO/ANSI/OSHPD/IEC
  • Microprocessor Based Control
  • Two Wire Start – Any Generator Controller
  • Service Entrance and Non-Service Entrance Rated

Electric

Electrical Ampere Rating: 100/200/400/600/800/100/1200 | 100/200/400/600/800/100/1200 480 V Any Breaker: 30 kA/30 kA/30 kA/50 kA/50 kA/50 kA/50 kA | 100/200/400/600/800/100/1200 480 Specific Breaker: 50 kA/50 kA/50 kA/65 kA/65 kA/65 kA/65 kA | 100/200/400/600/800/100/1200 600 V Any Breaker: 22 kA/22 kA/42 kA/42 kA/42 kA/42 kA/42 kA | 100/200/400/600/800/100/1200 660 V Specific Breaker: 35 kA/35 kA/65 kA/65 kA/65 kA/65 kA/65 kA | 100/200/400/600/800/100/1200 Rating When Used with Upstream Fuse, Rating: 100 kA/100 kA/200 kA/200 kA/200 kA/200 kA/200 kA | 100/200/400/600/800/100/1200 Rating When Used with Upstream Fuse, Test Voltage: 480 kA/600 kA/600 kA/600 kA/600 kA/600 kA/600 kA | 100/200/400/600/800/100/1200 Rating When Used with Upstream Fuse, Fuse Type: RK5/RK5/RK5/L/L/L/L | 100/200/400/600/800/100/1200 Rating When Used with Upstream Fuse, Maximum Fuse Amperes: 200/400/600/1200/1200/1600/1600 | 100–200 at 480/600V Standard Terminals, Normal AND eMERGENCY: (1) #6–350 MCM | 225–400 at 480V Standard Terminals, Normal and Emergency: (1) 3/0–750 MCM | 100–200 at 480/600V Standard Terminals, Load: (1) #6–350 MCM | 225–400 at 480V Standard Terminals, Load: (1) 3/0–750 MCM | 100–200 at 480/600V Standard Terminals, Neutral: (3) #6–350 MCM | 225–400 at 480V Standard Terminals, Neutral: (1) 3/0–750 MCM | 600–1200 Standard Terminals, Normal and Emergency: (2) 3/0–750 MCM/(2) 3/0–750 MCM | 600–1200 Standard Terminals, Load: (2) 3/0–750 MCM/(2) 3/0–750 MCM | 600–1200 Standard Terminals, Neutral: (12) 3/0–750 MCM/(12) 3/0–750 MCM

Dimensions

Height 100–200 at 480/600V: 78.07 in (1983.0 mm) | 225–400 at 480V: 78.07 in (1983.0 mm) | 600–1200: 90.00 in (2286.0 mm)/90.00 in (2286.0 mm)
Width 100–200 at 480/600V: 30.00 in (762.0 mm) | 225–400 at 480V: 30.00 in (762.0 mm) | 600–1200: 40.00 in (1016.0 mm)/40.00 in (1016.0 mm)
Depth, Maximum 100–200 at 480/600V: 29.30 in (744.2 mm) | 225–400 at 480V: 29.30 in (744.2 mm) | 600–1200: 28.99 in (736.3 mm)/44.47 in (1129.5 mm)

Weights

Weight 100–200 at 480/600V: 625 lbs (284 kg) | 225–400 at 480V: 625 lbs (284 kg) | 600–1200 (NEMA 1/NEMA 3R): 1800 lbs (817 kg) / 1850 lbs (840 kg)

Features

Features Double-throw, solenoid-operated transfer mechanism | Isolated Compartments for improved safety | Entry is top and/or bottom | Single motion rack-out with doors closed | Dual ATS capability – Bypass contactor can be controlled by the ATS controller in the bypass mode of operation. The design allows the switch controller to remain active in both the ATS and Bypass modes, thus providing control to either contactor. This ability of the controller to remain active to control the Bypass isolation contactor provides “N+1” redundancy of a second fully functioning ATS. | Field-selectable multi-tap transformer panel permits operation on a wide range of system voltages | Mimic diagram with Source Available and Connected LED indication | 4.3 inch Color Display | Event logging and recording 450 time-stamped events | System TEST pushbutton | Programmable plant exerciser | Modbus® RTU | 3-Phase under and over voltage sensing on normal and emergency sources, plus load | Under and over frequency sensing on normal, emergency and load | 3-Phase sequence sensing for phase sensitive loads | 3-Phase voltage unbalance and loss sensing | Source available: Source-1 Present, 2-N.O. & 2 N.C. / Source-2 Present, 2-N.O. & 2 N.C. | Switch position: Source-1 Position, 1-N.O. & 1-N.C. / Source-2 Position, 1-N.O. & 1 N.C. | Pre Transfer Contacts: 1-N.O. & 1 N.C. |