The Power Series Transfer Switch line features 3 different platforms with multiple technologies to offer the most flexible solutions up to 5,000 AMPs. All platforms are rated for 3 cycle operation with highly reliable mechanisms with safety interlocks. Service entrance models are 100 percent rated and available with integral overcurrent protection. These distinctive Generac models combine an automatic transfer switch with an isolation mechanism and a manual bypass switch to provide redundant power transfer and re-transfer capability for critical-need applications requiring consistent and uninterrupted power to the load.

Features may include:

  • 100 – 5000 Amp
  • Open with Time Delay Neutral or In-Phase Transfer
  • Closed Transition
  • Bypass Isolation
  • Contactor, Power Frame, or Molded Case Breaker
  • 2, 3, 4 Pole
  • NEMA 1, 12, 3R, 4 & 4X
  • UL1008/CSA/NFPA/NEC/ISO/ANSI/OSHPD/IEC
  • Microprocessor Based Control
  • Two Wire Start – Any Generator Controller
  • Service Entrance and Non-Service Entrance Rated

Electric

Electrical Amperes: 1,000-2,000/2,500-3,200 | 1,000-2,000/2,500-3,200 Poles | 1,000-2,000/2,500-3,200 Load Side, Normal and Standby Source: (6) 1/0-750 MCM Cu/Al / (9) 1/0-750 MCM Cu/Al | 1,000-2,000/2,500-3,200 Neutral Connection: (24) 4/0-500 MCM Cu/Al / (36) 4/0-500 MCM Cu/Al | UL 1008 Withstand and Closing Ratings Ampere Rating: 1,000/1,200/1,600/2,000/2,500/3,200/4,000 /5,000 | UL 1008 Withstand and Closing Ratings 1,000/1,200/1,600/2,000/2,500/3,200/4,000 /5,000 Rating When Used with Upstream Circuit Breaker (3 Cycle 600 V-30 Cycle 600 V): 100 kA-85 kA/100 kA-85 kA/100 kA-85 kA/100 kA-85 kA/100 kA-85 kA/100 kA-85 kA/100 kA-85 kA/-85 kA

Operational

Operating Temperature, Maximum -4 ° to 158 °F (-20 ° to 70 °C)

Dimensions

Height 1,000-2,000/2,500-3,200: 90.0 in (2,286 mm)/90.0 in (2,286 mm)
Width 1,000-2,000/2,500-3,200: 64.0 in (1,626 mm)/64.0 in (1,626 mm)
Depth, Maximum 1,000-2,000/2,500-3,200: 60.0 in (1,524 mm)- 75.0 in (1,905 mm)/60.0 in (1,524 mm)- 75.0 in (1,905 mm) / 60.0 in (1,524 mm)- 75.0 in (1,905 mm)/60.0 in (1,524 mm)- 75.0 in (1,905 mm)

Weights

Weight 1,000-2,000/2,500-3,200: 3,100 lbs (1,409 kg)- 4,100 lbs (1,864 kg)- 3,700 lbs (1,682 kg)- 4,700 lbs (2,136 kg) / 4,700 lbs (2,136 kg)- 5,700 lbs (2,591 kg)- 5,500 lbs (2,500 kg)- 6,500 lbs (2,955 kgs)

Features

Features 1,000-2,000/2,500-3,200 Enclosure Type (NEMA): 1-3R/1-3R / 1-3R/1-3R | Single Motion Rack-out with Doors Closed | Front Access | Cable Entry is Side, Rear, Top, and Bottom | Drawout Design | Isolated Compartments for Improved Safety | Mimic Diagram with Source Available and Connected LED Indication | Field-Selectable Multi-tap Transformer Panel Permits Operation on a Wide Range of System Voltages | Event Logging and Recording 450 Time-Stamped Events | System TEST Pushbutton | Programmable Plant Exerciser | Modbus® RTU | ATC-900 Controller | Three Phase Under and Over Voltage Sensing on Normal and Emergency Sources, Plus Load | Under and Over Frequency Sensing on Normal, Emergency, and Load | Three Phase Sequence Sensing for Phase Sensitive Loads | Three Phase Voltage Unbalance and Loss Sensing | Source Available: Source-1 Present, 1-N.O. and 1-N.C. / Source-2 Present, 1-N.O. and 1-N.C. | Switch Position: Source-1 Position, 1-N.O. and 1-N.C. / Source-2 Position, 1-N.O. and 1-N.C. | Up to 20 Parameters Available with Expandable Input/Output Modules | Monitor Mode | Bypass Timers | Lockout | Manual Retransfer On/Off | Manual Retransfer | Slave In | Remote Engine Test | Preferred Source Selection | Go to Emergency | Emergency Inhibit | ATS on Bypass | Go to Neutral | Load Sequence | Selective Load Shed | Load Bank Control | Pre/Post-Transfer | Pre-Transfer | User Remote Control | Source 1 Available (Standard) | Source 2 Available (Standard) | Source 1 Connected | Source 2 Connected | ATS Not in Automatic | General Alarm | ATS in Test | Engine Test Aborted | Cooldown in Process | Engine Start Contact Status | Generator 1 Start Status | Generator 2 Start Status | Emergency Inhibit On | ATS On Bypass