The Power Series Transfer Switch line features 3 different platforms with multiple technologies to offer the most flexible solutions up to 5,000 AMPs. All platforms are rated for 3 cycle operation with highly reliable mechanisms with safety interlocks. Service entrance models are 100 percent rated and available with integral overcurrent protection.

Features may include:

  • Standard — Provides fast transfers and is an economical and easy-to-use choice for most facilities.
  • Service Entrance — Provides a disconnect that interrupts excessive voltage and allows for manually disconnecting your facility from the electrical utility. Rated for full load transfers in critical operating, emergency, legally required, and power systems.
  • Bypass Isolation — Designed for transfer switch applications where maintenance must be performed while maintaining continuous power to the load.
  • Manual – Designed for applications having a need for a mobile generator, providing reliable and easy-to-use connections for safe and quick backup power connection.
  • 100 – 5000 Amp
  • Open with Time Delay Neutral or In-Phase Transfer
  • Closed Transition
  • Bypass Isolation
  • Contactor, Power Frame, or Molded Case Breaker
  • 2, 3, 4 Pole
  • NEMA 1, 12, 3R, 4 & 4X
  • UL1008/CSA/NFPA/NEC/ISO/ANSI/OSHPD/IEC
  • Microprocessor Based Control
  • Two Wire Start – Any Generator Controller
  • Service Entrance and Non-Service Entrance Rated

Electric

Electrical Power Frame Type, Closed Transition, 1,600 – 3,200 A, Fixed Mount Amperes: 1,600-2,000 / 2,500-3,200 | Power Frame Type, Closed Transition, 1,600 – 3,200 A, Fixed Mount 1,600-2,00/2.500-3,200 Poles: 3-4 / 3-4 | Power Frame Type, Closed Transition, 1,600 – 3,200 A, Fixed Mount 1,600-2,000/2,500-3,200 Load Side, Normal and Standby Source: (6) 1/0-750 MCM Cu/Al / (9) 1/0-750 MCM Cu/Al | Power Frame Type, Closed Transition, 1,600 – 3,200 A, Fixed Mount 1,600-2,000/2,500-3,200 Neutral Connection: (24) 4/0-500 MCM Cu/Al-(24) 4/0-500 MCM Cu/Al / (36) 4/0-500 MCM Cu/Al-(36) 4/0-500 MCM Cu/Al | Power Frame Type, Closed Transition, 1,600 – 5,000 A, Drawout Amperes: 1,600-2,000/2,500-3,200 | Power Frame Type, Closed Transition, 1,600 – 5,000 A, Drawout 1,600-2,000/2,500-3,200 Poles: 3-4 / 3-4 | Power Frame Type, Closed Transition, 1,600 – 5,000 A, Drawout 1,600-2,000/2,500-3,200 Load Side, Normal and Standby Source: (6) 1/0-750 MCM Cu/Al / (9) 1/0-750 MCM Cu/Al | Power Frame Type, Closed Transition, 1,600 – 5,000 A, Drawout 1,600-2,000/2,500-3,200 Neutral Connection: (24) 4/0-500 MCM Cu/Al / (36) 4/0-500 MCM Cu/Al | UL 1008 Withstand and Closing Ratings: 1,600/2,000/2500/3,000/3,200/4,000/5,000 | UL 1008 Withstand and Closing Ratings 1,600/2,000/2500/3,000/3,200/4,000/5,000 Rating When Used with Upstream Circuit Breaker (3 Cycle 600 V/30 Cycle 600 V): 100 kA/85 kA / 100 kA/85 kA / 100 kA/85 kA / 100 kA/85 kA / 100 kA/85 kA / 100 kA/85 kA / -/85 kA

Operational

Operating Temperature, Maximum -4 ° to 158 °F (-20 ° to 70 °C)

Dimensions

Height Power Frame Type, Closed Transition, 1,600 – 3,200 A, Fixed Mount 1,600-2,000/2,500-3,200: 90.0 in (2,286 mm) / 90.0 in (2,286 mm) | Power Frame Type, Closed Transition, 1,600 – 5,000 A, Drawout 1,600-2,000/2,500-3,200: 90.0 in (2,286 mm) / 90.0 in (2,286 mm)
Width Power Frame Type, Closed Transition, 1,600 – 3,200 A, Fixed Mount 1,600-2,000/2,500-3,200: 32.0 in (813 mm) / 44.0 in (1,118 mm) | Power Frame Type, Closed Transition, 1,600 – 5,000 A, Drawout 1,600-2,000/2,500-3,200: 32.0 in (813 mm) / 44.0 in (1,118 mm)
Depth, Maximum Power Frame Type, Closed Transition, 1,600 – 3,200 A, Fixed Mount 1,600-2,000/2,500-3,200: 48.0 in (1,219 mm) - 63.0 in (1,600 mm)/48.0 in (1,219 mm) - 63.0 in (1,600 mm) / 48.0 in (1,219 mm) - 63.0 in (1,600 mm)/48.0 in (1,219 mm) - 63.0 in (1,600 mm) | Power Frame Type, Closed Transition, 1,600 – 5,000 A, Drawout 1,600-2,000/2,500-3,200: 60.0 in (1,524 mm)-75.0 in (1,905 mm)/60.0 in (1,524 mm)-75.0 in (1,905 mm) / 60.0 in (1,524 mm)-75.0 in (1,905 mm)/60.0 in (1,524 mm)-75.0 in (1,905 mm)

Weights

Weight Power Frame Type, Closed Transition, 1,600 – 3,200 A, Fixed Mount 1,600-2,000/2,500-3,200: 1,050 lbs (477 kg)- 1,600 lbs (727 kg)/1,250 lbs (568 kg)- 1,800 lbs (818 kg) / 1,900 lbs (864 kg)-2,400 lbs (1,091 kg)/ 2,000 lbs (909 kg)- 2,500 lbs(1,136 kg) | Power Frame Type, Closed Transition, 1,600 – 5,000 A, Drawout 1,600-2,000/2,500-3,200: 1,600 lbs (727 kg)- 2,100 lbs (955 kg)/1,900 lbs (864 kg)-2,400 lbs (1,091 kg) / 2,500 lbs (1,136 kg)-3,000 lbs (1,364 kg)/2,800 lbs (1,273 kg)-3,300 lbs (1,500 kg)

Features

Features Power Frame Type, Closed Transition, 1,600 – 3,200 A, Fixed Mount 1,600-2,000/2,500-3,200 Enclosure Type (NEMA): 1-3R/1-3R / 1-3R/1-3R | Power Frame Type, Closed Transition, 1,600 – 5,000 A, Drawout 1,600-2,000/2,500-3,200: 1-3R/1-3R / 1-3R/1-3R | High Withstand and Closing Ratings | Safe Manual Transfer Under Load | Front Access | Cable or Bus Entry is Top, Bottom or Both | Isolated Compartments for Improved Safety | Mimic Diagram with Source Available and Connected LED Indication | Event Logging and Recording 450 Time-Stamped Events | System TEST Pushbutton | Programmable Plant Exerciser | Field-Selectable Multi-Tap Transformer Panel Permits Operation on a Wide Range of System Voltages | Modbus® RTU | ATC-900 Controller | Three Phase Under and Over Voltage Sensing on Normal and Emergency Sources | Three Phase Under and Over Voltage Sensing on Load | Under and Over Frequency Sensing on Normal and Emergency | Selectable Settings: Single or Three Phase Voltage Sensing on Normal, Emergency and Load 50 or 60Hz | Phase Sequence Sensing for Phase Sensitive Loads | Source Available: Source-1 Present, 1-N.O. and 1-N.C. / Source-2 Present, 1-N.O. and 1-N.C. | Switch Position: Source-1 Position, 1-N.O. and 1-N.C. / Source-2 Position, 1-N.O. and 1-N.C. | Up to 20 Parameters Available with Expandable Input/Output Modules | Monitor Mode | Bypass Timers | Lockout | Manual Retransfer On/Off | Manual Retransfer | Slave In | Remote Engine Test | Preferred Source Selection | Go to Emergency | Emergency Inhibit | Go to Neutral | Load Sequence | Selective Load Shed | Load Bank Control | Pre/Post-Transfer | Pre-Transfer | User Remote Control | Source 1 Available (Standard) | Source 2 Available (Standard) | Source 1 Connected | Source 2 Connected | ATS Not in Automatic | General Alarm | ATS in Test | Engine Test Aborted | Cooldown in Process | Engine Start Contact Status | Generator 1 Start Status | Generator 2 Start Status | Emergency Inhibit On