The Power Series Transfer Switch line features 3 different platforms with multiple technologies to offer the most flexible solutions up to 5,000 AMPs. All platforms are rated for 3 cycle operation with highly reliable mechanisms with safety interlocks. Service entrance models are 100 percent rated and available with integral overcurrent protection.

Features may include:

  • Standard — Provides fast transfers and is an economical and easy-to-use choice for most facilities.
  • Service Entrance — Provides a disconnect that interrupts excessive voltage and allows for manually disconnecting your facility from the electrical utility. Rated for full load transfers in critical operating, emergency, legally required, and optional power systems.
  • Bypass Isolation — Designed for transfer switch applications where maintenance must be performed while maintaining continuous power to the load.
  • Manual – Designed for applications having a need for a mobile generator, providing reliable and easy-to-use connections for safe and quick backup power connection.
  • 100 – 5000 Amp
  • Open with Time Delay Neutral or In-Phase Transfer
  • Closed Transition
  • Bypass Isolation
  • Contactor, Power Frame, or Molded Case Breaker
  • 2, 3, 4 Pole
  • NEMA 1, 12, 3R, 4 & 4X
  • UL1008/CSA/NFPA/NEC/ISO/ANSI/OSHPD/IEC
  • Microprocessor Based Control
  • Two Wire Start – Any Generator Controller
  • Service Entrance and Non-Service Entrance Rated

Electric

Electrical Amperes: 200-2,000/2,500-3,200 | Poles: 3-4/3-4 | Load Side, Normal and Standby Source 200-2,000/2,500-3,200: (6) 1/0-750 MCM Cu/Al / (9) 1/0-750 MCM Cu/Al | Neurtral Connection 200-2,000/2,500-3,200: (24) 4/0-500 MCM Cu/Al / (36) 4/0-500 MCM Cu/Al | UL 1008 Withstand and Closing Ratings Ampere Rating: 200-2,000/2,500/3,200/4,000/5,000 | UL 1008 Withstand and Closing Ratings 200-2,000/2,500/3,200/4,000/5,000 Ratin When Used with Upstream Circuit Breaker (3 Cycle 600 V-30 Cycle 600 V): 100 kA-85 kA/100 kA-85 kA/100 kA-85 kA/100 kA-85 kA/-85 kA

Dimensions

Height 200-2,000/2,500-3,200: 90.0 in (2,286 mm)
Width 200-2,000/2,500-3,200: 64.0 in (1,626 mm)
Depth, Maximum 200-2,000/2,500-3,200: 60.0 in (1,524 mm) - 75.0 in (1,905 mm)/60.0 in (1,524 mm) - 75.0 in (1,905 mm)

Weights

Weight 200-2,000/2,500-3,200: 3,100 lbs (1,409 kg)- 4,100 lbs (1,864 kg)- 3,700 lbs (1,682 kg)- 4,700 lbs (2,136 kg) / 4,700 lbs (2,136 kg)- 5,700 lbs (2,591 kg)- 5,500 lbs (2,500 kg)- 6,500 lbs (2,955 kg)

Features

Features Enclosure Type (NEMA): 1-3R/1-3R / 1-3R/1-3R | Single Motion Rack-out with Doors Closed | Interlocked Mechanism to Prevent Simultaneous Connection to Both Power Sources | Front Access | Cable Entry is Side, Rear, Top, and Bottom | Isolated Compartments for Improved Safety | Drawout Design | ATC-900 Controller | Mimic Diagram with Source Available and Connected LED Indication | Field-Selectable Multi-tap Transformer Panel Permits Operation on a Wide Range of System Voltages | Event Logging and Recording 450 Time-Stamped Events | System TEST Pushbutton | Programmable Plant Exerciser | Modbus® RTU | Three Phase Under and Over Voltage Sensing on Normal and Emergency Sources, Plus Load | Under and Over Frequency Sensing on Normal, Emergency, and Load | Three Phase Sequence Sensing for Phase Sensitive Loads | Three Phase Voltage Unbalance and Loss Sensing | Source Available: Source-1 Present, 1-N.O. and 1-N.C. / Source-2 Present, 1-N.O. and 1-N.C. | Switch Position: Source-1 Position, 1-N.O. and 1-N.C. / Source-2 Position, 1-N.O. and 1-N.C. | Up to 20 Parameters Available with Expandable Input/Output Modules | Monitor Mode | Bypass Timers | Lockout | Manual Retransfer On/Off | Manual Retransfer | Slave In | Remote Engine Test | Preferred Source Selection | Go to Emergency | Emergency Inhibit | ATS on Bypass | Go to Neutral | Load Sequence | Selective Load Shed | Load Bank Control | Pre/Post-Transfer | Pre-Transfer | User Remote Control | Source 1 Available (Standard) | Source 2 Available (Standard) | Source 1 Connected | Source 2 Connected | ATS Not in Automatic | General Alarm | ATS in Test | Engine Test Aborted | Cooldown in Process | Engine Start Contact Status | Generator 1 Start Status | Generator 2 Start Status | Emergency Inhibit On | ATS On Bypass