2025 Generac Mobile Stationary Generators SD050

2025 Generac Mobile Stationary Generators SD050

Swipe to View More

  • Year 2025
  • Make Generac Mobile
  • Model Stationary Generators
2025 Generac Mobile Stationary Generators SD050

2025 Generac Mobile Stationary Generators SD050

2025 Generac Mobile Stationary Generators SD050

Alternators are as important to power generation as engines. Generac's in-house built alternators are machine wound, machine inserted, and machine varnished for the ultimate in consistency. Available in single-phase or three-phase, the 50kW industrial diesel generator set provides 60-208amps of power. There are open set, standard enclosure, or Level 1 or 2 acoustic enclosure options. Made with a 4 cylinder engine, it features a Power Zone ® 410 Controller. 50kW generators have the power to backup essential equipment in small industrial or commercial buildings.

Features may include:

GENERATOR ENCLOSURE
  • Generac manufactures its own enclosures, ensuring each unit combines the highest level of durability, noise reduction, weather resistance, and streamlined design.
INDUSTRIAL ALTERNATOR
  • Generac industrial alternators are machine wound, machine inserted, and machine varnished for the ultimate in consistency.
POWER ZONE ® 410 CONTROLLER
  • Generac engineers its generator controls with safety and convenience as top priorities.

Engine

Engine Manufacturer Generac
Emissions EPA Emissions Compliance: Stationary Emergency | EPA Emissions Reference: See Emission Data Sheet
Cylinder Liners 4
Engine Type In-Line
Displacement 207.48 in3 (3.4 L)
Bore 3.86 in (98 mm)
Stroke 4.45 in (113 mm)
Compression Ratio 18.5:1
Cooling Type: Closed Recovery | Closed Coolant Recovery System | UV/Ozone Resistant Hoses | Factory-Installed Radiator | Radiator Drain Extension | 50/50 Ethylene Glycol Antifreeze | 120 VAC Coolant Heater
Engine Power Horsepower at Rated kW: 86 hp | Single-Phase 120/240 VAC @1.0pf: 50 kW / 208 Amps | Three-Phase 120/208 VAC @0.8pf: 50 kW / 173 Amps | Three-Phase 120/240 VAC @0.8pf. 50 kW / 150 Amps | Three-Phase 277/480 VAC @0.8pf: 50 kW / 75 Amps | Three-Phase 346/600 VAC @0.8pf: 50 kW / 60 Amps
Intake Design Intake Air Method: Turbocharged/Aftercooled
Governor Electronic Isochronous

Fuel System

Fuel Type Ultra Low Sulfur Diesel Fuel #2 | Specifications: ASTM
Fuel System Filtering (microns): 10 | Fuel Lockoff Solenoid | Primary Fuel Filter
Fuel Injection Type: Pintel - 2,100 psi (14,479 kPa)
Fuel Usage, 100% Load Diesel 25%: 1.3 gph (4.9 Lph) | Diesel 50%: 2.3 gph (8.7 Lph) | Diesel 75%: 3.3 hph (12.5 Lph) | Diesel 100%: 4.3 gph (16.4 Lph)

Battery

Battery Size: See Battery Index 0161970SBY | Voltage: 12 VDC
Battery Charger Input Standard

Electric

Electrical System Voltage: 12 VDC | Ground Polarity: Negative
Alternator Standard Model: K0050124Y21 | Poles: 4 | Field Type: Revolving | Insulation Class - Rotor: H | Insulation Class - Stator: H | Total Harmonic Distortion: <5% (3-Phase) | Telephone Interference Factor (TIF): < 50 | Standard Excitation: Synchronous Brushless | Bearings: Single Sealed Cartridge | Coupling: Direct via Flexible Disc | Load Capacity - Standby: 100% | Voltage Regulator Type: Digital | Regulation Accuracy (Steady State): ±0.25% | UL2200 GENprotect™ | 12 Leads (3-Phase, Non 600V) | Class H Insulation Material | Vented Rotor| 2/3 Pitch | Skewed Stator | Auxiliary Voltage Regulator Power Winding | Brushless Excitation | Sealed Bearing | Automated Manufacturing (Winding, Insertion, Lacing, Varnishing) | Rotor Dynamically Spin Balanced | Full Load Capacity Alternator | Protective Thermal Switch

Operational

Operating Conditions Frequency Regulation (Steady State): ±0.25%
Operating Speed Fan: 2,250 RPM | Rated Engine: 1,800 RPM | Piston: 1,335 ft/min (406.9 m/min)
Operating Temperature, Maximum Maximum Operating Ambient Temperature: 122 °F (50 °C) | Maximum Ambient Temperature (Before Derate): See Bulletin No. 0199280SSD | Exhaust Temp (Rated Output): 1,044 °F (562 °C)

Hydraulics

Pump Type Oil: Gear | Water: Pre-Lubed, Self Sealing | Inject: Bosch (VE) | Fuel: Engine Driven Gear
Oil Filter Type: Full Flow Cartridge
Hydraulic Flow Total Fuel Pump Flow (Combustion + Return): 3.6 gph (13.5 Lph) | Coolant: 12.2 gpm (46 Lpm) | Exhaust Flow (Rated Output): 448 scfm (12.7 m3/min)
Airflow Inlet Air: 7,500 scfm (212 m3/hr) | Flow at Rated Power: 166 scfm (4.7 m3/min)
Maximum Pressure Maximum Radiator Backpressure: 0.5 in H2O (0.12 kPa) | BMEP: 169 psi(1,165 kPa) | Max. Allowable Backpressure: 1.5 inHg (5.1 kPa)

Dimensions

Dimensions Fan Diameter: 560 in (22 mm) | Fuel Supply Line: 0.312 in (7.92 mm) NPT | Fuel Return Line: 0.312 in (7.92 mm) NPT | Fuel Pump Lift: 3 ft (1 m)

Capacities

Oil capacity Crankcase: 7.4 qt (7 L)
Cooling System Coolant Capacity: 2.5 gal (9.5 L)

Features

Features Fan Type: Pusher | Oil Drain Extension | Air Cleaner | Fan Guard | Factory Filled Oil and Coolant | Radiator Duct Adapter (Open Set Only) | Critical Silencer (Enclosed Units Only) | Battery Charging Alternator | Battery Cables | Battery Tray | Rubber-Booted Engine Electrical Connections | Solenoid Activated Starter Motor | Internal Genset Vibration Isolation | Separation of Circuits - High/Low Voltage | Separation of Circuits - Multiple Breakers | Wrapped Exhaust Piping | Standard Factory Testing | Silencer Mounted in the Discharge Hood (Enclosed Only) | Silencer of Heat Shield
Construction Material Cylinder Head: Cast Iron OHV | Piston Head: Aluminum | Crankshaft Type: Forged Steel | Stainless Steel Flexible Exhaust Connection

Warranty

Warranty 2 Year Limited Warranty (Standby Rated Units) | 1 Year Limited Warranty (Prime Rated Units)